空调移机步骤和注意事项
移机步骤
Moving steps
1.确定空调移动的位置,管度的长度是否足够。空调的安放位置是否适合,是否符合各种要求等。空调的重新移机也是需要符合一般安装空调位置的要求的。应该勘察好环境位置是否适合转移空调,再准备好需要的材料和器材。包括制冷修理工具一套,以及室内外机的固定用膨胀螺丝等材料。还有需要更新、延长等的管道等等。
1. Determine the position of the air conditioner moving and whether the
length of the tube is sufficient. Whether the position of air
conditioner is suitable and whether it meets various requirements. The
air conditioning transfer machine also needs to meet the requirements of
general installation air conditioning. You should check whether the
environment is suitable for the transfer of air conditioning and the
materials and equipment you need. Includes a set of refrigeration repair
tools, as well as fixed expansion screws for indoor and outdoor
machines. There are pipes that need to be updated, extended, etc.
2.回收制冷剂:把空调器中的制冷剂收集到室外机中去。拆机前应启动空凋器,可用遥控器设定制冷状态,待压缩机运转5-10分钟,制冷状态正常后,用扳手拧下外机的液体管与气体管接口上的保帽,关闭高压管(细)的截止阀门,l分钟后管外表结露,立即关闭低压管(粗)截止阀门,同的迅速关机,拔下电源插头,用扳手拧紧保险帽,至此回收制冷剂工作完成。也可采用室内机上的强制启动按钮开机,同的观察室内、外机是否还有其他故障。避免移机后带来麻烦。
2. Recovery refrigerant: collect refrigerant from air conditioner into
the outdoor machine. Teardown should start before air conditioning unit,
can use the remote control set of refrigeration, for compressor running
5-10 minutes, the refrigeration is normal, after using a wrench unscrew
the machine on the liquid pipe and gas pipe interface of cap, close the
high-pressure pipe cut-off valve (fine), l minutes condensation tube
appearance, immediately shut off the low pressure pipe (coarse) cut-off
valve, with the rapid shutdown, unplug the power plug, using a wrench,
tighten the insurance cap now recycle refrigerant work is done. You can
also use the mandatory start button on the indoor machine, and see if
there are any other problems with the indoor and external machine. Avoid
trouble after the transfer.
3.切断电源,观察外机有无障碍物,取下内机机罩,清理外机附近的物品。打开室内机壳观察内机过滤网有无灰尘及异味,清理过滤网等。
3. Cut off the power supply, observe whether the external machine has
obstacles, remove the inner machine hood, and clean the objects near the
machine. Open the inner shell to observe the filter net of dust and
smell, clean up the screen and so on.
4.制冷剂回收后,可拆卸室内机。用扳手把室内机连接锁母拧开,用准备好的密封钠子旋好护住室内机连接接头的丝纹,防止在搬运中碰坏接头丝纹;再用十字起拆下控制线。同时应做标记,避免在安装时接错。如果信号线或电源线接错,会造成外机不运转,或机器不受控制。内机挂板一般固定的比较牢固,卸起来比较困难;卸完取下挂板,置于平面水泥地再轻轻拍平、校正。
4. After the refrigerant is recovered, the indoor machine can be
disassembled. Use a wrench to unscrew the internal machine of the indoor
machine, and use the prepared sodium seal to protect the silk grain of
the connecting joint of the chamber, to prevent the touching of the silk
lines in the handling; Remove the control line with a cross. It should
also be marked to avoid errors during installation. If the signal line
or power cord is wrong, the machine will not operate, or the machine
will not be controlled. It is more difficult to remove the mounting
plate of the inner plane. After unloading, remove the hanging board and
gently pat and correct the flat surface cement.
5.拆室外机具有风险,请务必在有专业空调制冷维修工作人员的安全拆卸保证下拆卸。拧开外机连接锁母后,应用住备好的密封钠子旋好护往外机连接接头的丝纹。再用扳手松开外机底脚的固定螺丝。拆卸后放下室外机时,最好用绳索吊住,卸放的同时应注意平衡,避免振动、磕碰,并注意安全。应慢慢捋直室外空调器的接管,用准备好的四个堵头封住连接管的四个端口,防止空气中灰尘和水份进入。堵头上好,最后再用塑料袋扎好,盘好以便于搬运。
5. It is risky to remove the outdoor machine, please make sure that it
is disassembled under the safety of the professional air conditioning
refrigeration maintenance staff. Unscrew the outside machine to connect
the lock mother, apply the sealed sodium in the preparation to protect
the external machine to connect the wire. Use a wrench to loosen the
screws on the bottom of the machine. When disassembling and putting down
the outdoor machine, it is better to be able to hang with a rope, and
balance the discharge, avoid vibration, knock, and pay attention to
safety. The outdoor air conditioner should be slowly taken over and the
four ports of the connecting tube are sealed to prevent dust and water
from entering the air. Plug your head, and then wrap it in a plastic bag
so that you can handle it.
6.清理拆卸后的空调位置。清理空调的内外部。准备重新安装空调。
6. Clean up the disassembled air conditioner. Clean up the internal and
external air conditioning. Prepare to reinstall the air conditioning.
7.先安装好内机挂板,待外机与内机挂板安装牢固以后,再把连接管捋平直,查看管道是否有弯瘪现象;接下来应检查两端喇叭口是否有裂纹,如有裂纹,应重新扩口,否则会漏氟。最后,检查控制线是否有短路、断路现象,在确定管路、控制线、出水管良好后,把它们绑扎在一起并将连接管口密封好。过墙时应两个人在墙内、外配合缓慢穿出,避免拉伤;连接好管道与内、外机,并接好控制线。接下去,排除管道和内机中的空气。方法是这样;
7. Install the inner wall plate first, and after the external machine
and the inner machine wall are installed firmly, the connecting tube is
straightened out to see if the pipe has a bending phenomenon; The next
should check whether there are cracks on both ends of the horn, if there
is a crack, should reexpand the mouth, otherwise the fluorine will
leak. Finally, check whether the control line has short circuit or
circuit breakers. After determining the pipeline, control line, and
outlet pipe, tie them together and seal the joint pipe. When the wall is
over, two people should be in the wall inside and outside slowly to
wear out, avoid strain; Connect the pipeline with the inner and outer
machine, and connect the control line. Next, remove the air from the
pipe and inside. So here's the method;
(1)把连接好的外机接头拧紧(细),用专用扳手松开截止阀门的阀杆1圈左右;
(1) tighten the connected external connector (fine) and loosen the valve stem of the cut-off valve with a special wrench;
(2)听到外机接头(粗)吱吱响声,30 秒左右,用钣手拧紧(粗)接头;
(2) hearing the external joint (coarse) creaking, 30 seconds or so, using the plate hand to tighten the (coarse) joint;
(3)松开(粗)管上戴止阀门的阀杆;
(3) loosen the valve stem of the valve;
(4)彻底松开(细)管上截止阀门的阀杆。这时空凋器排空结束。
(4) completely loosen the stem of the valve in the tube. The chronometer is empty.
最后,用洗涤剂进行检漏,仔细观察每一个接头有无气泡冒出,验明系统确无泄漏后,旋紧阀门保险帽,即可开机试运行。
Finally, use the detergent to leak detection, carefully observe whether
each of the joints have the bubble to come out, the inspection system
does not leak, tighten the valve insurance cap, can start up the test
run.
8.在确保电压、电源符合规定的供应后,插电等3-5分钟,将遥控器设置在制冷模式,温度设定在最低的条件下,开机运行(最好在中午和下午试机)。空调运行后,将遥控器的风速开关设定在不同的档位上运行,观察内机有无异常噪音。开机运行15分钟左右观察外机风扇是否运转正常,外机有无异常噪音。开机运行
30分钟左右观察室内机出风有无冷风感,室外机出水管有无冷凝水流出,流水是否畅通。
8. After ensuring the supply of voltage, power supply in conformity with
the provisions, plug and so on for 3 to 5 minutes, set the remote
control in cooling mode, temperature setting under the condition of the
lowest, boot to run (preferably at noon and afternoon of commissioning).
After the air conditioning operation, the wind speed switch of the
remote control is set to run in different gear stalls to observe whether
the inner machine has abnormal noise. When the machine is up and
running for 15 minutes or so, observe whether the fan of the external
machine is working normally and the external machine has abnormal noise.
Start to run 30 minutes or so to observe whether the air in the chamber
of the air is cold and cold, the outside of the machine outlet water
pipe, whether the water flow out, the water flow unimpeded.
9.检查各种电流、电压是否符合空调的运行标准。
9. Check whether the current and voltage are in line with the operating standard of air conditioning.
10.空调移机的正常情况下可以不用加氟。如有需要可以一起加氟。如何加氟可以参见品牌空调网之前详细的介绍以及相关文章。
10. The air conditioner is normally free of fluoridation. Add fluorine
if necessary. How to add fluorine can see the brand air conditioning
network before detailed introduction and related article.
品牌空调网特别注意提醒:空调的移机程序复杂,本文提供让用户参考移机的操作的了解。但移动空调请找专业的空调安装维修人员来代劳。因为移动空调带有一定的危险性。并不适宜没有资格证的用户单独移动空调。
Brand air conditioning network special attention to remind: air
conditioning the mobile program is complex, this article provides the
understanding that lets the user reference the operation of the mobile
machine. But mobile air conditioning please find professional air
conditioning installation maintenance personnel to do the work. Because
mobile air conditioning carries certain danger. It is not suitable for
unlicensed users to move air conditioners separately.
空调移机注意事项:
Note for air conditioning transfer:
1.确保安装的地方是能符合安装空调的要求的,特别是稳固空调的室外机和室内机。两机之间的连接要密封,距离要短。确保转移的电线连接合格。
1. Ensure that the installation is in accordance with the requirements
of the installation of air conditioning, especially the indoor and
indoor machines that have solid air conditioning. The connection between
the two machines should be sealed and the distance is short. Ensure
that the transfer of wire is qualified.
2.排水管安装不合理,而致冷凝水无法排出,或者内机安装不平衡而引起冷凝水无法排出,排水管接头脱落、破裂而引起漏水。
2. Improper installation of drain pipes, which can not be discharged by
condensate water, or the inbalance of the internal machine, resulting in
the failure of the condensate water, the discharge of the pipe joint,
and the water leakage caused by the rupture.
3.在拆卸空调时,要注意氟利昂的回收,对于各个接头处要进行包扎,不能让水和杂物进入管道内部,影响以后的制冷。
3. When removing the air conditioner, pay attention to the recycling of
freon, to carry out the dressing of the various joints, not to allow
water and debris to enter the pipeline, and influence the later cooling.
4.连接内外机的铜管接头不密封,而引起漏氟,在使用一段时间后,就不能正常使用,而在慢漏的情况下要在一年后才会出现空调不能正常制冷制热。在安装过程中,操作不当,连接铜管发生折死现象,而导致系统内压力升高,引起压缩机发热、不正常停机,严重者引起压缩机发生烧毁。安装过程中,操作不当,导致连接铜管破裂而发生氟利昴泄漏,而引起完全不能制冷制热。
4. Connect copper pipe joint of inside and outside the machine does not
seal, leakage caused by fluorine, in use after a period of time, can't
normal use, and in the case of a slow leak air conditioning can only be
seen to be in a year can't normal refrigeration and heating. In the
process of installation, improper operation, connect copper tube folding
death occur, and result in higher system pressure, compressor caused by
fever, abnormal downtime, serious cause burn down compressor. In the
installation process, improper operation caused the copper tube to burst
and the fluorocarbon leak occurred, which caused the complete failure
of refrigeration and heating.
5.外机连接管时一定要排空,安装后没有排出空气,引起制冷制热效果不好,严重者在氟利昴的超低温下引起结冰颗粒,yo13udi8堵塞毛细管,而致空调完全不能使用,和不严格操作,灰尘进入氟利昴连接管,引起系统脏堵。而致空调不能正常使用。外机连接管若有空气混入压机导致制冷不良,连接管道一定要包扎完整,走管要横平竖直,保持整体美观。
5. The machine must empty, when connecting pipe after installation
without exhaust air, causing air conditioning refrigeration result is
bad, serious in fluorine the under cryogenic cause ice particles,
yo13udi8 jams capillary, and air conditioning can't use, and not strict
operation, dust into the fluorine, the connecting pipe, dirty plugging
in the system. The air conditioning cannot be used normally. If air
mixers have air mixers, it is necessary for the piping to be complete.
The pipe should be horizontal and vertical to maintain the overall
appearance.
品牌空调网建议用户需要搬运、移动空调最好找空调的维修商或者专业的维修商。因为空调移机是一个复杂的过程,因为省下移机费用而影响空调日后的使用质量就因小失大了。安装过程不得而当造成空调的维修费用也不低。所以用户最后找相熟的维修商来代劳。
Brand air conditioning network recommends that users need to move and
move air conditioning to find a maintenance or professional maintenance
provider. Because air conditioning is a complicated process, because of
the cost of the transfer of the air conditioner, the use of air
conditioning in the future will be lost. The installation process is not
allowed and the maintenance cost of air conditioning is not low. So the
user ends up looking for a mature repairer to do the work.